Gap Spacing in Frameless Shower Doors

Hi Chris

We’ve had our bathroom remodeled and I have a question about the frameless shower door. The glass was custom measured but when the door was installed the gap between the door and the adjacent glass isn’t uniform. It is 1/8″ at the top and 3/8″ at the bottom. I’ve asked the contractor to replace it. This doesn’t seem unreasonable. Also they put a plastic sweep along the edge. I think they did this to try and mask the gap. Is a sweep needed and normal?  Most pictures I’ve seen don’t have them.

You will also see in the picture silicone along the base of the shower glass we had the tile laid at a slight angle to allow Water to flow into the shower so I didn’t think this silicone is needed.  Your experience?

Thanks,

Brad

IMG_0129      IMG_0131

Hi Brad,

Sorry to hear about the issues you are having with your recent shower enclosure installation. I think it is reasonable to reject the 1/4″ difference in size of the gap between the door and fixed panel. The industry standard is 1/16″ – but I think even that is pushing it. The edge seal along that edge is probably there to hide the condition you are describing. I never use a plastic seal there unless it is requested by the homeowner.

I also try to avoid using silicone whenever possible… Again, unless the homeowner requests it, I won’t. A frameless shower enclosure is not intended to be completely water-tight. They are to be used in showers where a small amount of water escaping is acceptable. These are issues that I am careful to discuss with my customer at the time of the sale. I explain the options and always try to dissuade my customers from making me caulk the shower. In some spots it is unavoidable, but I will let them make that call. It is way easier to add silicone later, if it is needed, than it is to remove it after it has been applied.

Similar Posts

One Comment

  1. My builder installed a frameless shower door in 2 showers. There is an 1/2” gap between the wall and the glass where the 2 clips are holding the glass. The water goes through the gap onto the floor. I want them remeasured and replaced.